Overview
Run a standard winding on a driver it wasn't matched to and you leave real performance behind. A winding cut for your setup gets it back.
Winding Parameter Relationships
The winding parameters (turns, wire gauge, and series-versus-parallel connection) all pull on each other. Change one and the others move:
- More turns = higher voltage constant, lower current, higher inductance
- Fewer turns = lower voltage constant, higher current, lower inductance
- Larger wire gauge = lower resistance, higher current capacity, fewer turns
- Series connection = doubles voltage constant, same current
- Parallel connection = same voltage constant, doubles current capacity
Matching Winding to Driver
The right winding gets the most out of the voltage and current your drive actually has. For a current-limited drive (most servo drives), pick a winding that reaches rated current at the drive's voltage ceiling at your operating speed. For a voltage-limited drive (step/direction), go with lower inductance for better high-speed behavior.
Back-EMF voltage at speed: V_bemf = Ke × velocity. Required drive voltage: V_drive = V_bemf + I × R + I × L × dI/dt. Choose Ke so V_drive ≤ 80% of supply voltage at maximum speed.Requesting Custom Windings
Send Bravo Automation or Nippon Pulse your numbers: supply voltage, max current, target force, speed range, and duty cycle. Engineering will spec a winding and turn around custom-wound motors in about 4-6 weeks.
Typical applications
- Battery-powered systems (low voltage optimization)
- High-speed applications (low inductance winding)
- High-force applications (maximum current winding)
- Non-standard voltage systems
Related products