Overview
An I²T algorithm estimates motor heat. A sensor in the winding measures it. When you want the real temperature rather than a model, Copley drives can read a thermistor or RTD on an analog input and act on it before the motor is damaged.
Supported Temperature Sensors
Most servo motors ship with a temperature sensor embedded in the windings. Copley drives read:
- PTC Thermistors - Resistance increases sharply at trip temperature
- NTC Thermistors - Resistance decreases with temperature (10K NTC common)
- KTY84 Sensors - Linear silicon temperature sensors
- PT100/PT1000 RTDs - Precision platinum resistance sensors
Configuration in CME 2
Set this up on the analog input in CME 2. Switch the input mode to temperature sensor, pick the sensor type, and set a warning threshold and a fault threshold. The drive warns at the first and faults at the second.
For NTC thermistors: R(T) = R25 × exp(B × (1/T - 1/298.15)) where R25 is resistance at 25°C, B is the B-constant, and T is temperature in Kelvin.Thermal Derating
As the temperature nears the warning threshold, the drive can pull the current limit down on its own, which cuts heating while the axis keeps running. In a lot of applications that slow fade beats dropping out on a hard fault.
Typical applications
- High-ambient temperature environments
- Continuous-duty applications
- Motors without adequate cooling
- Safety-critical thermal monitoring
Related products