Overview
Grounding is one of the first things that goes wrong on a servo install and one of the last things people check. Get it wrong and you get noise pickup, ground loops, and intermittent faults that are miserable to chase. Here's how to wire the grounds so they don't bite you.
Ground Loop Prevention
A ground loop forms when two ground paths close a circuit that carries current you never intended. Between the drive, controller, and motor, that current couples into feedback signals and shows up as position errors or faults.
- Use a single-point (star) ground topology
- Connect all ground references to one common point
- Avoid daisy-chaining grounds between multiple drives
- Keep power ground and signal ground separated until the star point
Chassis Grounding
Bond every metal enclosure, DIN rail, and motor housing to protective earth (PE) with a low-impedance connection. Use flat braided strap, not round wire — braid has lower impedance at high frequency, which is where the noise lives. Scrape off paint or anodizing at the contact point so it's metal on metal.
Motor Cable Grounding
Run shielded motor cable and terminate the shield at both ends with a 360-degree clamp, not a pigtail. Land it on the drive's PE terminal and on the motor frame. Past about 25 meters, add ferrite cores at the drive end.
Typical applications
- New servo system installations
- Troubleshooting noise-related faults
- Multi-axis cabinet design
- EMC compliance preparation
Related products
All Copley servo drives. See them on the Copley Controls page or ask us for a quote.