Overview
Functional safety is about getting the drive into a safe state the moment something dangerous happens, to protect the people and hardware around it. Copley Accelnet Plus drives do this through STO (Safe Torque Off) and SBC (Safe Brake Control), both certified to SIL 3 (IEC 61508) and PLe (ISO 13849).
Safe Torque Off (STO)
STO is the base safety function. It takes away the drive's ability to make torque by cutting the power stage through a redundant hardware path that doesn't depend on firmware. On Accelnet Plus, STO runs off dual-channel inputs:
- Dual-channel redundant input architecture
- Response time < 10ms from input activation to torque removal
- Hardware-based implementation independent of firmware
- Diagnostic coverage (DC) > 99% per IEC 61508
- Category 4 / PLe per ISO 13849-1
Safe Brake Control (SBC)
SBC works with STO to hold the brake on vertical or gravity-loaded axes so the load can't drop. When STO fires, SBC sets the brake before torque goes away, so nothing falls in the gap.
Safety System Integration
To bring STO into a machine's safety system, wire its inputs to a safety PLC or safety relay that's watching the E-stops, light curtains, and the rest. Design the whole circuit to hit the Performance Level (PL) or Safety Integrity Level (SIL) the application calls for.
Typical applications
- Machine safeguarding per ISO 13849
- Vertical axis gravity protection
- Collaborative robot safety
- Emergency stop implementation
Related products