Overview
PWM switching makes a servo cabinet a noisy place, and your encoder feedback, command signals, and network traffic all have to stay clean through it. That comes down to which cable you run, how you route it, and how you terminate it.
Signal Cable Routing
Keep power and signal cable apart. Route encoder, communication, and analog command lines at least 200mm from motor power leads. Where they have to cross, cross at 90 degrees so they couple as little as possible.
- Maintain minimum 200mm separation between power and signal cables
- Route signal cables in separate cable trays or conduits
- Cross power cables at right angles only
- Keep signal cables as short as practical
Differential vs Single-Ended Signals
Differential signaling (RS-422, RS-485, differential encoders) shrugs off noise far better than single-ended. Copley drives take differential encoder inputs and differential analog commands. Use differential wherever you can, and definitely on long runs or in a noisy cabinet.
Encoder Cable Best Practices
Encoder cables are the touchy ones: a small distortion turns into a position error. Use shielded twisted-pair with an individual shield on each pair. Keep incremental encoder runs under 30 meters, and check the signal on CME 2's scope at the drive's own encoder inputs, not somewhere upstream.
Typical applications
- Encoder signal troubleshooting
- Cabinet wiring design
- Long cable run installations
- EMI-sensitive environments
Related products
Xenus Plus • Accelnet Plus • Stepnet. See them on the Copley Controls page or ask us for a quote.